Abstract

This study aimed to assess thermal comfort for workers in three buildings for wet coffee processing in Colombia, using the WBGT index, and temperature and relative humidity analysis through mapping. The limits recommended by the WBGT index were exceeded during the activity of putting fuel in the dryer in Building 3. The three buildings presented spatial hygrothermal variability due to the coffee dryer, as well as problems with ventilation, volume control, and the thermal resistance of materials in Buildings 2 and 3. In order to favor heat transfer from the dryer to the outside environment, and to make the thermal environment of these buildings more homogeneous, it is recommended to install thermal bridges around this area, to make more efficient the evacuation of steam and heat, as well as to increase the natural ventilation area in Buildings 2 and 3, and install ventilation skylights over the dryer.

Keywords:

References

Bitencourt, D., Ruas, A.C. & Maia, P. (2012). Análise da contribuição das variáveis meteorológicas no estresse térmico associada à morte de cortadores de cana-de-açúcar. Cadernos de Saúde Pública, 28(1), 65-74. doi: http://dx.doi.org/10.1590/S0102-311X2012000100007

Carvalho, C., dos Santos, T.C., da Silva, G.C. et al. (2014). Conforto térmico animal e humano em galpões de frangos de corte no semiárido mineiro. Revista Brasileira de Engenharia Agrícola e Ambiental, 18(7), 769-773. doi: http://dx.doi.org/10.1590/S1415-43662014000700015

Carvalho, C.C.S., Souza, C.F., Tinôco I.F.F. et al. (2011). Segurança, saúde e ergonomia de trabalhadores em galpões de frangos de corte equipados com diferentes sistemas de abastecimento de ração. Engenharia Agrícola, Jaboticabal, 31(3), 438-447. http://dx.doi.org/10.1590/S0100-69162011000300004

Ciro Velásquez, H., Cortés Rodríguez, M. & López Castaño, J. (2011). Secado de Café en Lecho Fijo con Intermitencia Térmica y Flujo de Aire Pulsado. Revista Facultad Nacional de Agronomía Medellín, 64(2). Retrieved from: https://revistas.unal.edu.co/index.php/refame/article/view/29417/37168

Evangelista, W.L. & Borges, L.J.A. (2015). Análise postural do setor de embalagens secundárias e expedição de um frigorífico típico da indústria suinícola do Brasil. Revista ação ergonômica, 10(1), 89-98. Retrieved from: http://www.abergo.org.br/revista/index.php/ae/article/view/468

Gonzalez, C.A., Sanz, J. R. & Oliveros C. E. (2010). Control de caudal y temperatura de aire en el secado mecánico de café. Cenicafé, 61(4), 281-296. Retrieved from: http://biblioteca.cenicafe.org/handle/10778/503

Herrera, J.A.A., Castellón, E.C., Barrera, L.M.T., Novoa, I.P.V. (2015). Evaluación de estrés térmico en una empresa productora de alimentos en Córdoba-Colombia. Revista Clepsidra, 10(19), 113-124. Retrieved from: http://revistas.fuac.edu.co/index.php/clepsidra/article/view/451. DOI: https://doi.org/10.26564/19001355.451

IDEAM. (2019). Atlas climatológico de Colombia. Retrieved from: http://atlas.ideam.gov.co/visorAtlasClimatologico.html

Iida, I. (2005). Ergonomia: projeto e produção. São Paulo, SP: Editora Blucher.

International Organization for Standardization. (2017). ISO 7243 - 2017: Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet-bulb globe temperature) index. Retrieved from: https://www.iso.org/standard/67188.html

Kottek, M., Grieser, J., Beck, C. et al. (2006). World map of the Köppen-Geiger climate classification updated. Meteorologische Zeitschrift, 15(3), 259-263. Doi: http://dx.doi.org/10.1127/0941-2948/2006/0130

Lamberts, R., Dutra, L. & Ruttkay, F.O.P. (2014). Eficiência Energética na arquitetura. 3rd ed. São Paulo: Pro Livros. Retrieved from: http://www.mme.gov.br/documents/10584/1985241/Livro%20-%20Efici%C3%AAncia%20Energ%C3%A9tica%20na%20Arquitetura.pdf

Lamberts, R., Xavier, A.A. & Goulart, S. (2008). Conforto e Stress Térmico. Laboratório de Eficiência Energética em Edificações, Santa Catarina: Departamento de Engenharia Cívil, Centro Tecnológico, Universidade Federal de Santa Catarina. Retrieved from: http://www.labeee.ufsc.br/antigo/arquivos/publicacoes/Apconforto.pdf

Lee, L. W., Cheong, M. W., Curran, P. et al. (2015). Coffee fermentation and flavor An intricate and delicate relationship. Food chemistry, 185, 182-191. Doi: https://doi.org/10.1016/j.foodchem.2015.03.124

Ministerio de Trabajo y Seguridad Social. (1979). Resolución 2400 de 1979, Disposiciones sobre vivienda, higiene y seguridad en los establecimientos de trabajo. Retrieved from: http://copaso.upbbga.edu.co/legislacion/Res.2400-1979.pdf

Ministério do Trabalho e Emprego. (2011). Norma Regulamentadora 15 Atividades e operações insalubres, Portaria n° 3.214 de 08 de junho de 1978. Texto atualizado pela Portaria SIT nº 291, de 08 de dezembro de 2011. Retrieved from: http://www.uneb.br/pgdp/files/2010/09/NR-15-Atividades-e-operacoes-insalubres1.pdf

Oliveros, C., Peñuela, A., Pabon, J. & Gravimet, S.M. (2013). Tecnología para medir la humedad del café en el secado en silos. Cenicafé, 433(1), 1-8. Retrieved from: https://www.cenicafe.org/es/index.php/nuestras_publicaciones/avances_tecnicos/avance_tecnico_0433

Osorio, R., Guerra, L.M., Tinôco, I.F.F. et al. (2016). Simulation of the internal environment of a post-harvest installation and a solar dryer of coffee. Revista Brasileira de Engenharia Agrícola e Ambiental, 20(2), 163-168. Doi: http://dx.doi.org/10.1590/1807-1929/agriambi.v20n2p163-168

Osorio, R., Aristizábal I.D., Osorio S. et al. (2019). Bioclimatic modeling for determining the minimum area of natural ventilation in buildings for the wet processing of coffee. DYNA, 86(208), 69-74. Doi: https://doi.org/10.15446/dyna.v86n208.63383

Osorio, R., Guerra, L.M., Tinôco, I.F.F. et al. (2015). Simulation of a thermal environment in two buildings for the wet processing of coffee. DYNA 82(194), 214-220. Doi: http://dx.doi.org/10.15446/dyna.v82n194.49526

Oviedo, N.E. & Torres, A. (2014). Atenuación hídrica y beneficios hidrológicos debido a la implementación de techos verdes ecoproductivos en zonas urbanas marginadas. Ingeniería y Universidad, 18(2), 291-308. Doi: http://dx.doi.org/10.11144/Javeriana.IYU18-2.hahb

Revueltas, M., Betancourt, J.A., del Toro, R. & Martínez, Y. (2015). Caracterización del ambiente térmico laboral y su relación con la salud de los trabajadores expuestos. Revista Cubana de Salud y Trabajo, 16(2), 3-9. Retrieved from: http://www.bvs.sld.cu/revistas/rst/vol16_2_15/rst01215.pdf

Rivero, R. (1986). Arquitetura e Clima: acondicionamento térmico natural. Porto Alegre, Brazil: Luzzatto Editores.

Roscani, R.C., Bitencourt, D.P., Maia, P.A. & Ruas, A.C. (2017). Risco de exposição à sobrecarga térmica para trabalhadores da cultura de cana-de-açúcar no Estado de São Paulo, Brasil. Cadernos de Saúde Pública, 33(3), 1-15. Doi: http://dx.doi.org/10.1590/0102-311x00211415

Todd, N. & Valleron, A.J. (2015) Space-time covariation of mortality with temperature: a systematic study of deaths in France, 1968-2009. Environmental Health Perspectives, 123(7), 659-664, Doi: http://dx.doi.org/10.1289/ehp.1307771

Viloria, A., Acuña, N., Mejia, H. & Galofre, M. (2016). Determination of the Influence of Thermal Comfort in Care and Concentration of Media Education Students: Case Colombia. Indian Journal of Science and Technology, 9(46), 1-5. Doi: http://dx.doi.org/10.17485/ijst/2016/v9i46/107374